• Switches
  • Circuit Breakers
  • Communication
  • Measuring
  • Capacitors
  • Modules
  • Socket
  • Decontactor
MTSE
Distribution board mounting on DIN rail standard 35 mm with cover plate 45 mm aperture, Handle/front plate black/silver.
Mechanical lifespan: >105 switching cycle.
Climatic resistance: damp heat, constant, to DIN IEC 60068-2-78 / damp heat, cyclic, to DIN IEC 60068-2-30
Ambient temperature: open: -25/+50 °C. (min/max) / enclosed: -25/+40 °C. (min/max)

DIN EN IEC 60947-6-1
260.00 260.0 ARS
MLS
Distribution board mounting on DIN rail standard 35 mm with cover plate 45 mm aperture, Handle/front plate black/silver.
Mechanical lifespan: >105 switching cycle.
Climatic resistance: damp heat, constant, to DIN IEC 60068-2-78 / damp heat, cyclic, to DIN IEC 60068-2-30
Ambient temperature: open: -25/+50 °C. (min/max) / enclosed: -25/+40 °C. (min/max)
210.00 210.0 ARS
1,300.00 1300.0 ARS
400.00 400.0 ARS
190.00 190.0 ARS
100.00 100.0 ARS
HART Smart Gateway
The G1100 WirelessHART intelligent gateway is responsible for establishment, management, and maintenance of WirelessHART networks. It continuously optimizes the network to ensure all devices work efficiently and safely. The WirelessHART intelligent gateway can seamlessly integrate the data of the devices in the network into the host system or the data application, and provide the corresponding security guarantee.
1,800.00 1800.0 ARS
HART Adapter
A1110 WirelessHART adapter (hereinafter referred to as A1110) is in line with the latest version of HART7.6 specification. It can seamlessly integrate the original HART equipment into WirelessHART network and protect the original assets. A1110 provides a variety of power supply modes, such as 4-20mA, external power supply, battery power supply and so on. A1110 makes all HART device data read access at any location possible, meanwhile it supports remote configuration and maintenance.
250.00 250.0 ARS
Temperature Transmitter (8 Ch)
NCS-TT108F/P temperature transmitter supports 8-channel temperature sensor input. It supports FF H1 and PROFIBUS PA protocols. With wide range, it can be applied to a variety of thermal resistance and thermocouple sensors.

NCS-TT108F/P temperature transmitter:

1. Support dual channel 4 types of thermal resistance and 8 types of thermocouple
2. Thermal resistance supports 2-wire and 3-wire
3. The cold junction compensation accuracy of voltage signal can reach ±1.0℃
4. High precision (better than grade 0.1), low temperature drift (better than ±50ppm/℃)
5. NCS-TT108 FF: FCG (FF ITK6) interoperability test, intrinsically safe, explosion-proof certification
6. NCS-TT108 PA: conform to PROFIBUS
450.00 450.0 ARS
27.00 27.0 ARS
AC Power Cap. (3F)
FRAKO power capacitors offer "Made in Germany" quality and are the optimal basis for both task-specific fixed installed capacity and controlled power factor correction systems. These power capacitors incorporate a quadruple safety system for maximum operational reliability. They are the first choice when consumers around the world
need to reduce reactive power, improve power quality and avoid reactive demand charges.
40.00 40.0 ARS
250.00 250.0 ARS
MCB (3/0,5 - 63 A/6 kA)
No. of poles (P): 3
Rated current = 0,5 - 63 A
Instantaneous tripping = TYPE B, C, D
Rated operational voltage (V) = 230/400AC
Rated shortcircuit breaking capacity (kA) = 6
Compliance standard = IEC 60898-1
130.00 130.0 ARS
RCCB (2P-25A)
No. of poles (P): 2(1+N)
Rated current = 25 A
Rated operational voltage (V) = 230/400AC
Compliance standard = IEC 61008-2-2
115.00 115.0 ARS
RCBO (1+N/3-40 A)
No. of poles (P): 2(1+N)
Rated current = 3-40 A
Instantaneous tripping = Type C
Rated operational voltage (V) = 230 AC
Rated shortcircuit breaking capacity (kA) = 6
Compliance standard = IEC 61009-2-2
230.00 230.0 ARS
Isolating Switch (1/32 A)
No. of poles (P): 1
Rated current = 32 A
Rated operational voltage (V) = 230/400AC
Compliance standard = IEC 60947-3
180.00 180.0 ARS
RCCB (2P-40A)
No. of poles (P): 2(1+N)
Rated current = 40 A
Rated operational voltage (V) = 230/400AC
Compliance standard = IEC 61008-2-2
115.00 115.0 ARS
RCCB (2P-60A)
No. of poles (P): 2(1+N)
Rated current = 60 A
Rated operational voltage (V) = 230/400AC
Compliance standard = IEC 61008-2-2
130.00 130.0 ARS
RCBO (1+N/6-40A)
No. of poles (P): 2(1+N)
Rated current = 6-40 A
Instantaneous tripping = Type C
Rated operational voltage (V) = 230 AC
Rated shortcircuit breaking capacity (kA) = 4,5
Compliance standard = IEC 61009-2-2
230.00 230.0 ARS
Política de Privacidad Política de Cookies